STANDARD SIZES for TUFNOL Filament Wound Cylinders
Sizes not listed may be available, subject to special order.
TUBES
Standard Sizes and Compression Loads*
Metric Size Range
|
Inside Diameter |
Outside Diameter |
Wall Thickness |
Cylinder Compression |
|
mm |
mm |
mm |
Load N |
|
25 |
29 |
2.0 |
3000 |
|
32 |
37 |
2.5 |
4000 |
|
40 |
45 |
2.5 |
5000 |
|
50 |
56 |
3.0 |
8000 |
|
63 |
69 |
3.0 |
10000 |
|
80 |
87 |
3.5 |
16000 |
|
100 |
107 |
3.5 |
20000 |
|
125 |
133 |
4.0 |
30000 |
|
160 |
169 |
4.5 |
40000 |
Imperial Size Range
|
Inside Diameter |
Outside Diameter |
Wall Thickness |
Cylinder Compression |
|
inch |
inch |
inch |
Load lbf |
|
1.00 |
1.16 |
0.080 |
700 |
|
1.50 |
1.70 |
0.100 |
1200 |
|
2.00 |
2.20 |
0.100 |
1600 |
|
2.50 |
2.74 |
0.120 |
2500 |
|
3.00 |
3.24 |
0.120 |
3000 |
|
4.00 |
4.28 |
0.140 |
5000 |
|
5.00 |
5.32 |
0.160 |
7000 |
|
6.00 |
6.36 |
0.180 |
10000 |
|
8.00 |
8.44 |
0.220 |
15000 |
|
10.00 |
10.52 |
0.260 |
22500 |
|
12.00 |
12.60 |
0.300 |
31000 |
|
16.00 |
16.76 |
0.380 |
52500 |
Note: Tube sizes outside our standard range can be produced and these are subject to special enquiry. Minimum production quantities may apply for certain items.
*See main FWT page
Back to main TUFNOL Filament Wound Tube page
Back to Home page
A full machining service is available from Tufnol for this and many other engineering plastics and composites.
Tufnol Composites Ltd, Wellhead Lane, Perry Barr, Birmingham B42 2TB, United Kingdom.
Quality Registration BS EN ISO 9001:2000, BS EN 9100:2003 and AS 9100 Reg. No. FM 90942
The information given here is believed to be correct, but completeness and accuracy are not guaranteed. The user shall be fully responsible for determining the suitability of products for the intended use.
| Home page | Legal page | Contact us | TUFNOL is a Registered Trade Mark. Copyright © 2000 – 2005 Tufnol Composites Ltd. All rights reserved. |